Suchergebnisse

Suchergebnisse 1-5 von insgesamt 5.

  • Zitat von Gregor: „Had the new plates the same software revision? Otherwise they don´t work correct. “ Software number old 19 . New was 1.9. I think it is the same. Just dot not visible on the label

  • DLS - Litauen, Vilnius Delonghi service "Baltic continent". Then I called DL distributor. The manager asked me to scan the invoice and to desrcibe the problem for him by email. He will sent the data to somebody who supervice the DL service network in our region. So I can't do anything , I decided to replace PCB with new one at our DLS. It will take one to three weks to get the part and will cost 130 Euro part plius install and 18.82 Euro diagnostic labour. The parts price at DTS was 64.35 Euro p…

  • Yesterday I bring the machine to DLS. Today they said that must replace mainboard. I asked : why you replace the new one? No ansver, just replace without explanation. Is it possible to test mainboard or return the part to seller? I am sure it is progaming problem. If not, I wish to make present (the part by post) for you or anybody from your friends who repair and need new part. It seems delonghi service can't change program so decide order new from factory. part number 5232109900 dts-online24.d…

  • Hello Stefan, thanks for quick post. I did not remove thermoblock. It fitted as from factory and never replaced. It heats normally and sits in place fixed to main body. Infuser assembly normally starts from middle (grinder) position and goes to the thermoblock and slide about 80% to the thermoblock piston. Then motor stops. It seems the PCB switch off motor due to revolution count. Then Infuser goes down to the lower microswitch and then up to main position (for remove). Then display shows "Inse…

  • Hallo, After short junction in milk microswitch to body "minus" all electronics burned out and all plates plates replaced. Main board, display board and hall sensor plate. Power up "Seft test" is OK. Ater heating up and motor run to upper position display shows trouble message "Insert infuser assembly". Infuser inserted but do not reach the highest point, upper limit switch about 5 milimeters. "Service mode" all works OK, motor goes normal down and up. Both swiches works OK. Upper switch wors OK…